尊敬的(de)用户,欢迎(ying)您(nin)选购(gou)我们的(de)产品(pin),感(gan)谢您(nin)的(de)信任和支(zhi)持。为了您(nin)更方便的(de)操作本设(she)备,提高生产效(xiao)率(lv),保证生产安(an)(an)全以及良好的(de)维护设(she)备,请在安(an)(an)装使用前认真阅读(du)并妥善保存本说明书!
伴随我国工(gong)业的(de)迅猛发展,产品(pin)的(de)性能(neng)不断升级,众多生(sheng)产厂家对感(gan)应加(jia)热设备的(de)要求(qiu)愈来愈高。全数(shu)字(zi)化控(kong)(kong)制电(dian)源取(qu)代模(mo)拟控(kong)(kong)制电(dian)源,高端感(gan)应加(jia)热设备取(qu)代传统低端设备,已(yi)成为(wei)改进升级的(de)必(bi)然选(xuan)择。
公司在(zai)分析借(jie)鉴国内(nei)外众多设(she)备(bei)优点的(de)基础上,结(jie)合国内(nei)工(gong)业(ye)现场的(de)实(shi)际应(ying)(ying)用(yong)需求,整合了(le)先进的(de)适(shi)用(yong)于(yu)感应(ying)(ying)加热(re)的(de)电子(zi)电路(lu)技(ji)术(shu),使用(yong)新一代电力电子(zi)功(gong)率(lv)器件IGBT作为串联谐振(zhen)逆(ni)变(bian)器的(de)开(kai)关(guan)器件,并应(ying)(ying)用(yong)了(le)先进的(de)DSP电子(zi)控制技(ji)术(shu),打造出具(ju)有自主知识产权的(de)新型全数字串联谐振(zhen)感应(ying)(ying)加热(re)设(she)备(bei),用(yong)于(yu)实(shi)现交(jiao)流电能的(de)频率(lv)转(zhuan)换和功(gong)率(lv)控制,广泛应(ying)(ying)用(yong)于(yu)兵器工(gong)业(ye)、航空(kong)航天(tian)、汽(qi)车、冶金、矿山(shan)、工(gong)程(cheng)机械、轻工(gong)等各(ge)个领域。
公司以其完美的(de)产品设(she)计(ji)、精心的(de)设(she)备制造(zao)和完善(shan)的(de)售后服(fu)务(wu)为众(zhong)(zhong)多(duo)(duo)企业(ye)(ye)创(chuang)造(zao)了良好的(de)社会效益(yi)(yi)和经济(ji)效益(yi)(yi),多(duo)(duo)年来为国内外众(zhong)(zhong)多(duo)(duo)企业(ye)(ye)提供了性能卓(zhuo)越的(de)各(ge)种感应加热(re)电源及成套设(she)备。
DSP智(zhi)能感应加热设备,其额定功率涵盖(gai)20--2MW,输出频(pin)率在中频(pin)、超音频(pin)、高(gao)频(pin)等频(pin)率段,可在5-50kHz的频(pin)率段定制。
我公(gong)司生产的(de)系列DSP智能(neng)感应加热电源设备的(de)技术性(xing)能(neng)指标居国内领先水平(ping),具有以下性(xing)能(neng)特点:
技(ji)术成熟,消化(hua)吸收了国(guo)外(wai)先进技(ji)术,根据国(guo)内(nei)具体(ti)情(qing)况进行(xing)设计,启(qi)动成功率高(gao)(100%)、整机效(xiao)率高(gao)(≥95%);
控(kong)制(zhi)性能好,频率范围宽(5~50kHz)、功(gong)率可平滑(hua)连(lian)续(xu)调(diao)节(10~100%额定(ding)功(gong)率),负载(zai)(zai)采用串联逆(ni)变谐振回路,电路简单、运行可靠、调(diao)整方便,对(dui)负载(zai)(zai)适(shi)应能力(li)强适(shi)应范围宽,适(shi)用于间断(duan)工(gong)作(zuo)及长(zhang)期(qi)工(gong)作(zuo)制(zhi),满足了工(gong)业现(xian)场的需要;
集成电(dian)路一体化设(she)计,电(dian)路抗(kang)干扰性能非(fei)常(chang)优秀(xiu),整体稳定(ding)性良好,长期(qi)使(shi)用(yong)性能可靠(kao)。
采用(yong)精确相位(wei)控(kong)制方式进(jin)(jin)行频率跟(gen)踪(zong),先进(jin)(jin)的(de)相位(wei)跟(gen)踪(zong)算法(fa),加(jia)热不同尺寸的(de)工件时相位(wei)始终保持最(zui)优(you),优(you)于同类产品;
采用基(ji)于(yu)ASIC设计的双路IGBT驱动器(qi),具(ju)有(you)故(gu)障(zhang)记忆、故(gu)障(zhang)软关断和故(gu)障(zhang)连锁功能,保证IGBT工作安全(quan)。
控制(zhi)电路采用国际知名品牌集成电路控制(zhi),具有(you)各(ge)种参数(shu)显示记(ji)录的功能,线路简(jian)单,工艺先进(jin),可(ke)靠性高;
操作简单,功率(lv)调(diao)(diao)整只(zhi)需(xu)调(diao)(diao)旋(xuan)钮(niu)(niu)或(huo)由机(ji)床给定,生产时只(zhi)需(xu)按启动、停(ting)止钮(niu)(niu),如与机(ji)床联(lian)机(ji)可(ke)按程序自动生产;
完善(shan)的保护(hu)电路(lu)和措施(shi),除了过(guo)流、过(guo)压保护(hu)外,还(hai)设(she)有频率跟(gen)踪(zong)失锁(suo),功能齐全,保护(hu)迅速可靠。
工作原理
工作原理是首先通(tong)过三相(xiang)不控整流(liu)桥和滤波电路将(jiang)三相(xiang)380V/50Hz交流(liu)电变换成直流(liu)电压(ya)源,再(zai)将(jiang)五百多伏的(de)直流(liu)滤波,最后通(tong)过单相(xiang)逆(ni)变电路转(zhuan)换成单相(xiang)交流(liu)电供给负(fu)载。
负载是指感应器(qi)-工(gong)(gong)件(jian)系统,感应器(qi)一般是通(tong)入(ru)超(chao)音(yin)频(pin)或(huo)高频(pin)交(jiao)流(liu)电的(de)由空(kong)心通(tong)水冷却(que)铜管绕(rao)制(zhi)的(de)线圈(quan),将工(gong)(gong)件(jian)放到(dao)感应器(qi)内即置(zhi)工(gong)(gong)件(jian)于交(jiao)变磁场中(zhong)(zhong),应用电磁感应原理(li)产生涡流(liu)损耗而(er)发热(re)(re),达到(dao)熔炼、透热(re)(re)、淬火等加热(re)(re)的(de)要(yao)求。这(zhei)种加热(re)(re)方(fang)式(shi)(shi)(shi)相(xiang)对于采用加热(re)(re)组件(jian)对工(gong)(gong)件(jian)加热(re)(re)方(fang)式(shi)(shi)(shi)而(er)言,具有加热(re)(re)速度(du)快(涡流(liu)加热(re)(re)而(er)非传导方(fang)式(shi)(shi)(shi)),加热(re)(re)效率高(能(neng)量(liang)集中(zhong)(zhong)损失小(xiao)),加热(re)(re)区(qu)域可控(通(tong)过电流(liu)频(pin)率、功率以及感应器(qi)形状等的(de)调整可得到(dao)理(li)想(xiang)的(de)加热(re)(re)层深(shen))等优点(dian)。根据用户不同的(de)需求,负载的(de)形式(shi)(shi)(shi)和特点(dian)也(ye)各不相(xiang)同,这(zhei)里主要(yao)对电源设(she)备工(gong)(gong)作原理(li)作简要(yao)说明。
本装置应安装于室内,并满足以下条件:
设备周围环境温度应不(bu)超(chao)过+40℃、不(bu)低于+5℃;
周(zhou)围介(jie)质(zhi)湿度应(ying)不超过85%(相对于空气温(wen)度20±5℃时(shi));
无导电及易爆(bao)(bao)炸尘埃(ai),无腐蚀(shi)性气体(ti)和(he)爆(bao)(bao)炸性气体(ti)的场合;
安装于通风良好,无剧烈震动和冲击,垂直倾斜度不超过5°的场(chang)合;
安装(zhuang)在(zai)通风良好、不(bu)受雨水侵袭的室(shi)内,并应留出一(yi)定的检测和维修空间(jian)
u安装前检查
设备运到后,应首先检(jian)查(cha)电源经过(guo)长途运输后所有紧固零件(jian)是(shi)否松动或脱落,所有元件(jian)及仪表有无损坏,有否受潮(chao)等现象,如发现上述情(qing)(qing)况应进行整修。在(zai)确保电源及其他配(pei)套(tao)件(jian)外观检(jian)查(cha)情(qing)(qing)况良(liang)好(hao)后,用户方可安(an)装(zhuang)使用。
冷却水要求
电源装(zhuang)置、感应器、淬火变压器、补(bu)偿用电热电容器等均采用水(shui)(shui)(shui)冷却,所提供的(de)冷却水(shui)(shui)(shui)状(zhuang)况的(de)好(hao)坏直接影响设备运行的(de)可(ke)靠性,建议(yi)使用闭(bi)式循环(huan)软化(hua)水(shui)(shui)(shui)。冷却水(shui)(shui)(shui)质的(de)要求为:
机械特(te)性:透明,不(bu)浑浊,无沉(chen)淀(dian)物(wu),总(zong)固体含量不(bu)超过250mg/L;
化(hua)学特性(xing):PH值为6~8,硬(ying)度不大于10度(即每(mei)升水(shui)中氧化(hua)钙含量(liang)≦100mg);
电阻率:大于2.5kΩ/cm;
进水温(wen)度:不(bu)低于(yu)5℃,不(bu)高于(yu)35℃,冷却水的(de)温(wen)升不(bu)超过20℃;
进水压力:0.15~0.3MPa;
冷(leng)却(que)(que)水(shui)质(zhi)最(zui)低要达到(dao)生活饮用水(shui)标准,最(zui)好选用工业锅炉软化水(shui)和纯净水(shui)。不能(neng)直接使用地表(biao)水(shui)和井水(shui),因为未经处理的(de)(de)地表(biao)水(shui)和井水(shui)往往带有泥(ni)(ni)沙(sha)和各类悬(xuan)浮物(wu),极易造(zao)成(cheng)水(shui)路堵塞。如果水(shui)中带有泥(ni)(ni)沙(sha)、铁锈、纤(xian)维、毛发等物(wu)将严(yan)重堵塞设备冷(leng)却(que)(que)管(guan)道,造(zao)成(cheng)水(shui)流量(liang)减小甚至无水(shui)流量(liang),冷(leng)却(que)(que)效(xiao)果变(bian)差,引起设备内部功(gong)率(lv)器(qi)件烧(shao)(shao)损(sun),造(zao)成(cheng)设备故障(zhang),给客户造(zao)成(cheng)损(sun)失。高硬(ying)度水(shui)质(zhi)或石(shi)灰岩水(shui)质(zhi)中含有大量(liang)的(de)(de)钙、镁等离子,长时间工作,设备内部的(de)(de)散热器(qi)及冷(leng)却(que)(que)管(guan)道中将形成(cheng)厚(hou)厚(hou)的(de)(de)水(shui)垢(gou),影响(xiang)水(shui)的(de)(de)冷(leng)却(que)(que)作用,同样会(hui)导致设备内部功(gong)率(lv)器(qi)件烧(shao)(shao)损(sun)。
冷却(que)水(shui)(shui)是电源系统工(gong)作的必要条(tiao)件,冷却(que)水(shui)(shui)水(shui)(shui)质、水(shui)(shui)压(ya)(ya)等(deng)应(ying)满足要求,若使用循环水(shui)(shui)冷却(que)时水(shui)(shui)应(ying)定期更新,并严格防止固(gu)体杂物(wu)混(hun)入冷却(que)水(shui)(shui)。电源冷却(que)水(shui)(shui)进出水(shui)(shui)在(zai)机柜(ju)顶(ding)部右(you)上方,进出水(shui)(shui)管径2”,进水(shui)(shui)应(ying)装调(diao)(diao)节阀门以(yi)便(bian)调(diao)(diao)节进水(shui)(shui)压(ya)(ya)力(li)(li),压(ya)(ya)力(li)(li)表在(zai)机柜(ju)左侧。
配套件中的(de)电(dian)热电(dian)容(rong)器(qi)(qi)也是水冷(leng)元(yuan)器(qi)(qi)件,流量约(yue)为1T/h。淬火(huo)变压器(qi)(qi)及感(gan)应器(qi)(qi)冷(leng)却水应按(an)厂家(jia)说明书(shu)要求配置,保(bao)证循环水的(de)温度流量正常,否则容(rong)易造(zao)成(cheng)严(yan)重(zhong)的(de)设(she)备损坏事故。
冷却水供给是设(she)(she)备(bei)正常工作(zuo)和耐(nai)用的(de)关键,进入设(she)(she)备(bei)的(de)冷却水温(wen)度(du)不能超过(guo)35℃,水压不能低于(yu)(yu)0.15MPa,进出水管要(yao)保证(zheng)畅通无阻。当(dang)设(she)(she)备(bei)进水温(wen)度(du)高于(yu)(yu)设(she)(she)定值时(shi),设(she)(she)备(bei)将(jiang)(jiang)报(bao)警停止工作(zuo)。过(guo)高的(de)水温(wen)将(jiang)(jiang)影响设(she)(she)备(bei)内的(de)全固态器件寿命,严(yan)重时(shi)将(jiang)(jiang)造(zao)成器件损坏(huai)。
我公司建议循环使用设(she)备(bei)的(de)冷(leng)却(que)(que)水,可以配(pei)置冷(leng)却(que)(que)塔或(huo)专用换热设(she)备(bei),设(she)备(bei)的(de)出水进(jin)入(ru)冷(leng)却(que)(que)塔或(huo)专用换热设(she)备(bei)冷(leng)却(que)(que),之后(hou)从设(she)备(bei)入(ru)水口重新进(jin)入(ru)设(she)备(bei)。相关冷(leng)却(que)(que)塔或(huo)换热设(she)备(bei)的(de)配(pei)置请(qing)咨询我公司。
电气安装
供电
电(dian)源装置输入供电(dian)为(wei)三相380V,电(dian)网电(dian)压应(ying)为(wei)正弦(xian)波(bo),谐(xie)波(bo)失真不(bu)大于5%,电(dian)压持(chi)续波(bo)动范围不(bu)超(chao)过±10%,电(dian)网电(dian)压的频(pin)率变化(hua)不(bu)超(chao)过±2%,三相电(dian)压相间不(bu)平衡度应(ying)小(xiao)于±5%。
电(dian)(dian)(dian)源(yuan)(yuan)(yuan)进线(xian)应(ying)有配(pei)(pei)电(dian)(dian)(dian)盘,配(pei)(pei)电(dian)(dian)(dian)盘要装快速(su)空气断路器,供电(dian)(dian)(dian)源(yuan)(yuan)(yuan)使用(yong)和维修时(shi)能(neng)接(jie)通或断开(kai)三(san)相(xiang)(xiang)(xiang)进线(xian)电(dian)(dian)(dian)源(yuan)(yuan)(yuan)。三(san)相(xiang)(xiang)(xiang)进线(xian)的(de)截(jie)面(mian)应(ying)符(fu)合线(xian)电(dian)(dian)(dian)流的(de)要求,三(san)相(xiang)(xiang)(xiang)进线(xian)应(ying)按顺序接(jie)入电(dian)(dian)(dian)源(yuan)(yuan)(yuan),地线(xian)应(ying)接(jie)到(dao)电(dian)(dian)(dian)源(yuan)(yuan)(yuan)内部的(de)相(xiang)(xiang)(xiang)应(ying)螺(luo)栓上。电(dian)(dian)(dian)源(yuan)(yuan)(yuan)的(de)控制电(dian)(dian)(dian)源(yuan)(yuan)(yuan)开(kai)关(guan)和主电(dian)(dian)(dian)源(yuan)(yuan)(yuan)开(kai)关(guan)处于断开(kai)位置(zhi),配(pei)(pei)电(dian)(dian)(dian)盘向(xiang)电(dian)(dian)(dian)源(yuan)(yuan)(yuan)供电(dian)(dian)(dian),本电(dian)(dian)(dian)源(yuan)(yuan)(yuan)有相(xiang)(xiang)(xiang)序自(zi)适应(ying)功能(neng),不(bu)需要调(diao)整相(xiang)(xiang)(xiang)序,打(da)开(kai)主电(dian)(dian)(dian)源(yuan)(yuan)(yuan)开(kai)关(guan)即可工(gong)作。
负载部分包括补(bu)偿电(dian)容、输出变(bian)压器(qi)及感应器(qi),因(yin)电(dian)流(liu)很大,电(dian)气连接不好(hao)易造成(cheng)连接处过(guo)热损坏,因(yin)此其电(dian)气连接必须绝对良好(hao)可靠。
接地线
按接(jie)(jie)(jie)(jie)地(di)(di)(di)要(yao)求(qiu),用6mm2以上铜线,将设备接(jie)(jie)(jie)(jie)地(di)(di)(di)端与大地(di)(di)(di)可靠(kao)连接(jie)(jie)(jie)(jie),绝(jue)不允许(xu)地(di)(di)(di)线与电源(yuan)零线混(hun)接(jie)(jie)(jie)(jie)。接(jie)(jie)(jie)(jie)地(di)(di)(di)端应与工厂配置的地(di)(di)(di)线网就近相接(jie)(jie)(jie)(jie)或单独用长1.5米以上的接(jie)(jie)(jie)(jie)地(di)(di)(di)锚,就近打地(di)(di)(di)桩接(jie)(jie)(jie)(jie)地(di)(di)(di)。接(jie)(jie)(jie)(jie)地(di)(di)(di)电阻(zu)小于4Ω。
其他
设(she)备停止使用期间,应(ying)(ying)加强(qiang)通风和干燥(zao)措施,以免(mian)内(nei)部受(shou)潮而造成损坏,在室内(nei)可能结冻的情况下,应(ying)(ying)把设(she)备内(nei)所有的冷却水清除干净
1)额定输入:三相380V±5%、地线6mm²
2)供电频率:50Hz
3)输(shu)出频率:5KHz~50kHz(可(ke)定制);
4)输(shu)出功率因数:≥98%
5)功率输出范围:5%~100%
6)工作制式:适用于间断(duan)工作及长期工作制;
7)电源冷却水(shui)压力及(ji)流量:0.15Mpa~0.3Mpa,3T/h;
8)冷却水温度:25℃~35℃
9)环(huan)境温(wen)度:+5℃ ~ +45
设备面板上有(you)操(cao)作按钮(niu)、旋(xuan)钮(niu),分(fen)别(bie)是加热/停止、功率(lv)旋(xuan)钮(niu)和(he)电源开关(guan)。各功能如下:
加热开始:上电后,在没有(you)故障时(shi),顺(shun)时(shi)针旋转,设备(bei)开始加热。在设备(bei)有(you)故障报(bao)警时(shi),设备(bei)无法(fa)加热。必须先排(pai)除故障原(yuan)因(yin),
加热停止:设备(bei)正(zheng)在(zai)加(jia)热时逆时针旋转停止加(jia)热。
复位/点动按钮:按(an)下该(gai)按(an)钮清除故(gu)障、或者(zhe)启动定时加(jia)热。
功率调节:按(an)照±刻度调(diao)节功(gong)率大小。
定时模式: 在时间设(she)定框下图(5 )输入要加热的时间, 按下点动加热开关(guan),开始加热,时间到,停止加热。
温控模式:时间设(she)(she)定设(she)(she)置为0 顺(shun)时针旋转加(jia)热(re)旋钮,开始(shi)加(jia)热(re),达到设(she)(she)定温度保持。
多(duo)功能显示屏(ping)简(jian)介
主界面(mian)显(xian)示
1、振荡电流(liu)——设备工作时实时直流(liu)电流(liu)
2、功率(lv)—— 设备工作时(shi)实(shi)时(shi)功率(lv)
3、频率(lv)——显示正常工作(zuo)时的(de)工作(zuo)频率(lv),单位(KHz)
4、加(jia)热计(ji)时(shi)——在时(shi)间控制模式 ,按(an)下(xia)脚(jiao)踏开(kai)关 计(ji)时(shi)显示。
5、时间设(she)定(ding)——在时间控(kong)制模式,设(she)定(ding)计(ji)时的时间
6、当前温(wen)度(du)(du)——在温(wen)度(du)(du)控制模式(shi),显示实时温(wen)度(du)(du)
7、设定(ding)温(wen)度——在温(wen)度控制模式,设定(ding)需要加热的(de)温(wen)度
8、预留
9、停止(zhi)按钮——在温(wen)度(du)控制或者时间控制模(mo)式 ,点(dian)击停止(zhi)按钮,设(she)备停止(zhi)工作
10、功率给定(ding)百分比(bi) ——显示给定(ding)的功率百分比(bi)
11、功率(lv)输(shu)出百分比—— 显示功率(lv)输(shu)出的(de)百分比
12、故(gu)障复位—— 设备故(gu)障时,按(an)下此按(an)钮 故(gu)障清除(chu)
13、菜单—— 可以调(diao)出(chu)一些(xie)参数(shu)设置
系统参数界面
1、启动(dong)频(pin)率—— 设备启动(dong)的扫频(pin)开始频(pin)率
2、停止(zhi)频率—— 设备启(qi)动的扫频停止(zhi)频率
3、振荡电流(liu)—— 设备(bei)工作(zuo)时的环路振荡电流(liu) (可(ke)手动输(shu)入(ru))
4、延(yan)时配置—— 信号的时间修正
5、相(xiang)位角—— 锁相(xiang)角度
6、变比—— 振(zhen)荡电(dian)流互感器采样匝比
7、比例—— PID调节专用(yong)
8、积分—— PID调节专用
9、微(wei)分—— PID调节专用
10、P_hw —— 温度PID调节专用(yong)
11、I_hw —— 温度PID调(diao)节专用(yong)
12、D_hw —— 温度PID调节专用
13、测温(wen)仪下(xia)限——测温(wen)仪的温(wen)度下(xia)限 (4-20ma)
14、测温仪上(shang)限——测温仪的温度上(shang)限 (4-20ma)
保护参数界面
1、最(zui)(zui)大功率—— 设备的最(zui)(zui)大输出功率
2、最大电流—— 设(she)备的(de)最大振荡电流
3、合闸时间—— 系统上电后多少秒后吸合断路器(单(dan)位:秒)
4、调试(shi)测试(shi)——温控pid用
5、报(bao)警电流—— 振荡电流报(bao)警门限
6、最大直(zhi)流—— 直(zhi)流霍尔传感器(qi)最大量程((4-20mA输入)0-1200A)
7、扫(sao)频速(su)度—— 启(qi)动时,频率下降的(de)速(su)度
8、频(pin)率选择—— 4分(fen)频(pin) 最低(di)(di)3.6K 8分(fen)频(pin) 最低(di)(di)1.8K 16分(fen)频(pin) 最低(di)(di)0.9K (设(she)备工作(zuo)中(zhong)不(bu)要设(she)置,设(she)置完(wan)毕重启设(she)备)
9、占(zhan)空比(bi)—— 设备启动时脉冲宽度 2 为(wei)全开 7为(wei)最窄
设备调试界面
1、登(deng)陆—— 登(deng)陆后可以修改一些(xie)参数
2、退(tui)(tui)出—— 退(tui)(tui)出后(hou)参数不能设置(zhi)
安装使用和维护
负载频率匹(pi)配和阻抗匹(pi)配的调整
如前(qian)所述,串联谐振电(dian)路(电(dian)源负载)的(de)(de)谐振频率(lv)及谐振时(shi)的(de)(de)阻(zu)抗为(wei):
在(zai)额定频率条件(jian)下(xia),电(dian)源(yuan)要求负(fu)载的固有频率略(lve)低于电(dian)源(yuan)的额定工(gong)作频率,这就是(shi)电(dian)源(yuan)和负(fu)载之间(jian)的频率匹配(pei)。另(ling)外,电(dian)源(yuan)要求在(zai)额定电(dian)压(三相(xiang)整流桥最高输出(chu)电(dian)压为(wei)Vd=530伏)和额定输出(chu)电(dian)流Id的情况下(xia)才能够输出(chu)额定功(gong)率,即等效直流阻(zu)抗=Vd/Id要合适,而(er)取决于负(fu)载参数,这就是(shi)电(dian)源(yuan)和负(fu)载之间(jian)的阻(zu)抗匹配(pei)。
串联谐振回路的(de)(de)(de)电容(rong)(rong)量(liang)可按电源(yuan)(yuan)的(de)(de)(de)输出功(gong)率确(que)定,一般(ban)来说电容(rong)(rong)器(qi)总的(de)(de)(de)视在功(gong)率等于(yu)4~6倍(bei)的(de)(de)(de)电源(yuan)(yuan)输出功(gong)率,例如(ru),电源(yuan)(yuan)输出功(gong)率是200KW则电容(rong)(rong)器(qi)的(de)(de)(de)容(rong)(rong)量(liang)应该是1200KVA,淬火变压器(qi)的(de)(de)(de)容(rong)(rong)量(liang)应是电源(yuan)(yuan)输出功(gong)率的(de)(de)(de)3~4倍(bei)。然后根据感应器(qi)的(de)(de)(de)几何形状和尺寸凭经验(yan)选择(ze)淬火变压器(qi)初次级(ji)之间的(de)(de)(de)匝比(bi)。
本电(dian)(dian)源有(you)负载(zai)自适应功能(neng),在不上(shang)主电(dian)(dian)状态(tai)下(xia),调(diao)整好负载(zai)之后,在电(dian)(dian)源内控模(mo)式下(xia)加热,上(shang)位显示屏(ping)自动(dong)给(ji)出负载(zai)的匹(pi)配状态(tai)及谐振频率供用户参(can)考调(diao)试(shi)。
操作程序
1.接通冷却水进水,并使(shi)水压表压力指示大(da)于0.15Mpa,补(bu)偿电容器(qi),淬火(huo)变压器(qi)及(ji)感(gan)应加热器(qi)均接通冷却水,每(mei)次(ci)开机(ji)前都必须检查加热负载的通水情(qing)况。
2.前(qian)述各步操(cao)作(zuo)完毕后电(dian)源上电(dian)接(jie)通主电(dian)接(jie)触器,操(cao)作(zuo)电(dian)源机柜上的启(qi)动(dong)和停(ting)止按钮,或者由机床控(kong)制(zhi)部分给出的启(qi)停(ting)信号控(kong)制(zhi)电(dian)源的工作(zuo)。
3.在下班完全停用电源(yuan)时,要(yao)断开主电源(yuan)开关。
维护与保管
1)电(dian)源在(zai)(zai)未拆箱(xiang)前应存放在(zai)(zai)空气流通,环境温(wen)度(du)不(bu)高于(yu)+40℃,不(bu)低于(yu)-20℃,相对(dui)湿度(du)不(bu)大于(yu)85%及无腐蚀气体的仓库中。
2)电(dian)源在长期停止使用(yong)时(shi)应该需先排除冷(leng)却水(shui)系统(tong)中(zhong)的积水(shui)。电(dian)源在使用(yong)期间天冷(leng)时(shi)要注意(yi)保温(wen)或冷(leng)却水(shui)循(xun)环(huan)不(bu)停来防(fang)止各(ge)部分冷(leng)却水(shui)路冻裂损坏。
3)电源应定(ding)期(qi)清除灰(hui)尘和油污,特别是灰(hui)尘中可能(neng)存在金属(shu)粉末的(de)场(chang)合,清除时注意(yi)不要损伤机内接线及零部(bu)件,定(ding)期(qi)检查机柜内部(bu)及负载(zai)部(bu)分的(de)每(mei)个电器连接点及冷却(que)水管有无松(song)动、有无因过热变色的(de)迹(ji)象,发现问(wen)题及时处(chu)理。
4)天气潮(chao)湿或(huo)水温(wen)与室(shi)温(wen)相(xiang)差(cha)较大(da)时应防(fang)止(zhi)功率器件表面凝露,上(shang)述现象要在通冷却水后注(zhu)意观(guan)察,如果凝露应通风吹干(gan)。
在使用中如(ru)发现故障(zhang)现象要冷静地分析故障(zhang)原(yuan)因,排(pai)除故障(zhang),不要盲目地大拆大动,只(zhi)要对(dui)电(dian)源各环(huan)节(jie)的(de)(de)作用有一定的(de)(de)了解,仔细分析与检查(cha),各种故障(zhang)是(shi)容易排(pai)除的(de)(de)。